AC Motors
RPM
App.
Over- F.L.
%
“C”
60 NEMA
Catalogue
Wgt.
Load Amps F.L.
Dim.
HP Hz Frame
Number
(lbs.)
Voltage
Prot. 230V Eff.
(in.)
1/2
1800 56
111917
L
:
25
208-230/460 None 1.8 78.5 11.31
1
1800 56
111918
:
29
208-230/460 None 3.8 77.0 12.46
RPM
App.
Over-
F.L.
%
“C”
60
NEMA
Catalogue
Wgt.
Load
Amps F.L. Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
230V
Eff.
(in.)
1/2
1800 S56
100145
22 208-230/460 None 2.0 68.0 10.81
1800 S56H
100796
&
22 208-230/460 Auto.
2.0 68.0 11.31
1800 S56H
100828
22
575
None 0.9 68.0 10.81
3/4
3600 S56H
101641
&
20 208-230/460 Auto.
2.4 79.0 11.31
1800 S56H
100146
25 208-230/460 None 2.8 75.0 11.31
1800 S56H
100908
&
26 208-230/460 Auto.
2.8 75.0 11.81
1800 S56H
100829
25
575
None 1.2 75.0 11.31
1
3600 56
113895
&
25 208-230/460 Auto.
3.2 77.0 10.81
1800 56
110052
23 208-230/460 None 4.2 78.5 11.31
1800 56H
111311
&
27 208-230/460 Auto.
4.2 78.5 11.31
1800 S56H
111393
31
575
None 1.4 78.5 11.81
1
1
2
3600 56H
113896
&
29 208-230/460 Auto.
4.2 81.5 11.82
1800 56H
110433
32 208-230/460 None 5.6 78.5 11.81
1800 56H
113846
&
29 208-230/460 Auto.
5.6 78.5 11.81
2
3600 56H
113897
&
39 208-230/460 Auto.
5.6 82.9 12.32
1800 56H
113847
&
34 208-230/460 Auto.
6.2 78.5 12.31
3
3600 56HZ
113926
&
40 208-230/460 Auto.
7.6 84.0 13.19
1800 56HZ
116593
&
47
230/460
Auto.
8.6 82.5 14.19
/ ÊUÊ/ , Ê* -
RESILIENT BASE
4OTALLY ENCLOSED FAN COOLED DESIGN MAKES
these motors ideal for replacement in tough
industrial applications where contaminants
cause failure of open drip-proof designs.
, *‡*,"" ÊUÊ/ , Ê* - Ê
RESILIENT BASE
Drip-proof design and resilient mount. Moderate
starting torque. Suitable for general purpose
applications.
RPM
App.
Over-
F.L.
“C”
60
NEMA
Catalogue
Wgt.
load
Amps
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
230V
(in.)
1/2
1800 56
110025
26
115/208-230 Auto. 4.4 11.96
3/4
1800 56
110026
:
28
115/208-230 Auto. 5.4 12.46
1
1800 56H
111915
:
31
115/208-230 Auto. 6.4 12.96
RPM
App.
Over-
F.L.
“C”
60
NEMA
Catalogue
Wgt.
load
Amps
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
230V
(in.)
1/4
3600 48
16 115/208-230 Auto.
2.0
9.38
1800 48
100109
17 115/208-230 Auto.
2.7
9.89
1800 48
17 115/208-230 Auto.
2.7
9.89
1/3
3600 48
17 115/208-230 Auto.
2.3
9.39
1800 48
100110
18 115/208-230 Auto.
3.3
9.89
1800 48
18 115/208-230 Auto.
3.3
9.89
1800 S56
100014
19 115/208-230 None
3.3 10.31
1800 S56
100010
18 115/208-230 Auto.
3.3 10.31
1800 S56
19 115/208-230 Auto.
3.3 10.31
1/2
3600 48
19 115/208-230 Auto.
4.2 10.38
1800 S56
100015
21 115/208-230 None
4.4 10.81
1800 S56
20 115/208-230 Man.
4.4 10.81
1800 S56
100011
22 115/208-230 Auto.
4.4 10.81
1800 S56
20 115/208-230 Auto.
4.4 10.81
3/4
3600 48
22 115/208-230 Auto.
4.8 10.39
3600 S56H
100603
26 115/208-230 Auto.
4.9 11.31
1800 S56H
100016
26 115/208-230 None
5.4 11.81
1800 S56H
100046
26 115/208-230 Man.
5.4 11.81
1800 S56H
25 115/208-230 Man.
5.5 11.31
1800 S56H
100012
26 115/208-230 Auto.
5.4 11.81
1800 S56H
25 115/208-230 Auto.
5.5 11.81
1
3600 56H
110478
28 115/208-230 Auto.
6.0 11.85
1800 56H
113027
30 115/208-230 None
6.4 11.81
1800 56H
110007
29 115/208-230 Auto.
6.4 11.81
1800 56H
32 115/208-230 Auto.
6.4 11.81
1
1
2
3600 56H
110479
30
115/230
Auto.
8.2 11.82
1800 56H
110579
)
:
38 115/208-230 Auto
7.2 12.82
2
3600 56H
113633
38 115/208-230 Auto. 10.0 13.82
1800 56H
113608
)
45 115/208-230 Auto. 10.0 13.81
66
, - /Ê - Ê "/",-ÊUÊ- Ê* - ÊUÊ/ , Ê* -
'%.%2!, 0520/3% /2 &!. ",/7%2 3%26)#% s -/$%2!4% 34!24).' 4/215%
4HESE MOTORS HAVE .%-! 3ERVICE &ACTORS EXCEPT AS
NOTED BY WHICH HAVE A 3ERVICE &ACTOR AND
4%&# MOTORS WHICH HAVE A 3ERVICE &ACTOR
'ENERAL 3PECIFICATIONS
Industrial quality, resilient (cradle) mounted, capacitor start-type, ball bearing motors for fan and blower service. Moderate starting torque electrical design to reduce
STRESS ON FAN BLADES DURING START UP 3UITABLE FOR BELT DRIVEN FANS OR FAN ON SHAFT APPLICATIONS 3ELF VENTILATED DESIGN MAY BE MOUNTED OUTSIDE OF THE FAN S AIRFLOW
3INGLE 0HASE
Capacitor-type design has higher energy efficiency rating than split phase, single phase fan and blower motors.
4HIRD 0HASE
For 277-volt, three phase service, the thermally-protected motors listed may be field-reconnected for operation without the thermal overload protector.
# These motors have a NEMA 1.00 Service Factor, suitable for blower
and fan duty.
)
Capacitor start/capacitor run design for reduced amperage, others
are capacitor start/induction run.
L
These motors are totally enclosed, non-ventilated.
:
Combination 56 H base motors have mounting holes for NEMA 56
and NEMA 143-5T and a standard NEMA 56 shaft.
&
Automatic reset overload protection. Reconnectable for 277 volt
operation without overload protection.
/ ÊUÊ- Ê* - Ê
RESILIENT BASE
4OTALLY ENCLOSED FAN COOLED DESIGN MAKES THESE
motors ideal for replacement in tough agricultural
and industrial applications where contaminants
cause failure of open drip-proof motors.
, *‡*,"" ÊUÊ- Ê* - Ê
RESILIENT BASE
Drip-proof design and resilient mount. Moderate
starting torque. Suitable for general purpose
applications.
1...,462,463,464,465,466,467,468,469,470,471 473,474,475,476,477,478,479,480,481,482,...1665