Butt’s Pumps and Motors - page 480

74
Specifications are subject to change without notice
AC Motors
Features:
s !UTO 0ROTECTOR
s #APACITOR 3TART
s #LASS " )NSULATION
s /PEN $RIPPROOF
s 2OTATION ##7 0UMP %ND
s
3TAINLESS 3TEEL 4HREADED 3HAFT
s 5,
$ESIGN
s 3EALED "ALL "EARINGS
s # !MBIENT
SQS1072
Important:
1. Total output (HP x Service Factor) of replacement motor
must equal or exceed motor being replaced.
2. The pool motors on this page are not equipped with
an SVRS (Safety Vacuum Release System). Please
contact your local distributor if required by law or pool
configuration.
SQUARE FLANGE POOL FILTER MOTORS
47/ #/-0!24-%.4 s 3).',% 47/ 30%%$
SQ1032
SQ1152
- Ê-* ÊUÊ
Ê- ,6 Ê
/",Ê­ 1 Ê, / ®
RPM
App.
Over-
“AG”
60
NEMA
Catalogue
Wgt.
load
Service
Max
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
Factor
Amps
(approx.)
Notes
1/3
3600 48Y
SQ1032
16
115/230
Auto
1.95
8.2/4.1
9.63
1/2
3600 48Y
SQ1052
19
115/230
Auto
1.90
11.8/5.9
10.38
3600 48Y
QC1052
1
24
115/230
Auto
1.90
9.6/4.8
10.88
20,$
3/4
3600 48Y
SQ1072
21
115/230
Auto
1.65
14.8/7.4
10.88
3600 48Y
QC1072
1
27
115/230
Auto
1.65
12.6/6.3
11.25
20,$
1
3600 48Y
SQ1102
26
115/230
Auto
1.65
19.2/9.6
11.88
3600 48Y
QC1102
1
30
115/230
Auto
1.65
16.0/8.0
11.88
20,$
1
1
2
3600 48Y
SQ1152
1
30
230
Auto
1.47
10.4
11.88
20,$
2
3600 48Y
SQ1202
1
32
230
Auto
1.30
11.2
12.63
20,$
3
3600 56Y
SQ1302V1
45
230
Auto
1.15
15.4
14.34
20,$
NOTES:
20. $ Energy Efficient capacitor start, capacitor run “Conservationist” motor
1 Capacitor start/run
2 Two speed shipped less hi/lo switch for remote operation
- Ê-* ÊUÊ "7Ê- ,6 Ê
/",Ê­1*Ê, / ®
RPM
App.
Over-
“AG”
60
NEMA
Stock
Wgt.
load
Service
Max
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
Factor
Amps
(approx.)
Notes
1/2
3600 48Y
USQ1052
16
115/230
Auto
1.30
9.9/5.0
11.13
3/4
3600 48Y
USQ1072
19
115/230
Auto
1.27
13.4/6.7
11.50
3600 48Y
UQC1072
25
115/230
Auto
1.27
9.6/4.8
10.88
20,$
1
3600 48Y
USQ1102
22
115/230
Auto
1.25
15.3/7.6
12.13
3600 48Y
UQC1102
30
115/230
Auto
1.25
12.6/6.3
11.25
20,$
1
1
2
3600 48Y
USQ1152
26
115/230
Auto
1.10
19.2/9.6
13.13
3600 48Y
UQC1152
30
115/230
Auto
1.10
16.0/8.0
13.25
20,$
2
3600 48Y
USQ1202
31
230
Auto
1.10
10.4
13.25
20,$
2
1
2
3600 48Y
USQ1252
32
230
Auto
1.00
11.2
13.88
20,$
/7"Ê-* ÊUÊ
Ê- ,6 Ê
/",Ê­ 1 Ê, / ®
RPM
App.
Over-
“AG”
60
NEMA
Catalogue
Wgt.
load
Service
Max
Dim.
HP
Hz
Frame
Number
(lbs.) Voltage
Prot.
Factor
Amps
(approx.) Notes
3/4~1/8
3600/1725 48Y
SQL1072R
1,2
28
115
Auto
1.65 13.0/4.2 12.63 20,$
3/4~1/8
3600/1725 48Y
SQS1072R
2
28
230 Auto
1.60
6.1/2.1 12.63
1~1/6
3600/1725 48Y
SQS1102R
2
33
230
Auto
1.65
7.7/2.8 13.81
1
1
2
~1/4
3600/1725 48Y
SQS1152R
1,2
35
230
Auto
1.47 10.0/3.0 13.81 20,$
2~1/3
3600/1725 56Y
SQS1202R
1,2
43
230
Auto
1.30 11.3/3.3 13.81 20,$
/7"Ê-* ÊUÊ "7Ê- ,6 Ê
/",Ê­1*Ê, / ®
RPM
App.
Over-
“AG”
60
NEMA
Catalogue
Wgt.
load
Service
Max
Dim.
HP
Hz
Frame
Number
(lbs.) Voltage
Prot.
Factor
Amps
(approx.) Notes
1~1/6
3600/1725 48Y
UQS1102R
2
28
230
Auto
1.25
6.1/2.1 13.13 20,$
1
1
2
~1/4
3600/1725 48Y
UQS1152R
1,2
33
230
Auto
1.10
9.5/2.5 13.81 20,$
2~1/3
3600/1725 48Y
UQS1202R
1,2
35
230
Auto
1.10 10.0/3.0 13.81 20,$
1...,470,471,472,473,474,475,476,477,478,479 481,482,483,484,485,486,487,488,489,490,...1665