AC Motors
ÊUÊ- ,Ê, / ʙäÊEÊ£näÊ6" /-
/ 6ÊUÊ Ê
Ê7 / Ê, "6 Ê -
Full
App.
Arm.
Control
F.L.
“C”
Load
NEMA
Catalogue
Wgt.
Volts
Volts
Amps
Dim.
HP
RPM
Frame
Number
(lbs.)
DC
AC
DC
(in.)
1/4
1800 S56C
108423
23
90
115
2.7 10.69
1800 S56C
098375
21 180
230
1.4 10.22
1/3
1800 S56C
108424
26
90
115
3.5 11.69
1800 S56C
098376
22 180
230
1.7 10.22
1/2
1800 S56C
108226
38
90
115
4.9 13.69
1800 S56C
108227
43 180
230
2.4 13.69
3/4
1800 S56C
108228
53
90
115
7.0 15.69
1800 S56C
108229
50 180
230
3.5 15.69
1
1800 S56C
108230
**
45
90
115
10.0 15.81
1800 S56C
108231
**
42 180
230
5.0 14.81
1
1
2
1800 S56C
108232
**
50 180
230
7.6 16.81
- Ê* - ÊUÊ/ ÊUÊ Ê
Ê7 / Ê -
RPM
App.
Over-
F.L.
“C”
60
NEMA
Catalogue
Wgt.
load
Amps
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
230V
(in.)
1/4
1800 56C
112525
27 115/208-230
None
2.4 10.69
1/3
3600 56C
113580
27 115/208-230
None
2.6 10.69
1800 56C
112526
28 115/208-230
None
3.2 10.69
1/2
3600 56C
113581
25 115/208-230
None
3.6 10.69
1800 56C
112527
27 115/208-230
None
4.4 11.19
3/4
3600 56C
113582
31 115/208-230
None
5.0 11.69
1800 56C
112528
30 115/208-230
None
5.4 11.69
1
3600 56C
113583
31 115/208-230
None
6.0 12.19
1800 56C
112529
33 115/208-230
None
6.4 12.19
1
1
2
3600 56C
113584
36 115/208-230
None
8.5 12.69
1800 56HC
113300
45 115/208-230
None
9.5 13.69
2
3600 56HC
114637
45 115/208-230
None
10.0 13.69
- Ê* - ÊUÊ/ ÊUÊ, Ê -
Featuring Electronic Solid State Encapsulated Switch
RPM
App.
Over-
F.L.
“C”
60
NEMA
Catalogue
Wgt.
load
Amps
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
Prot.
230V
(in.)
1/2
1800 56
112431
24 115/208-230
None
4.4
10.81
3/4
1800 56
112432
31 115/208-230
None
5.4
11.31
1
1800 56
112626
33 115/208-230
None
6.4
11.81
1800 143T
120589
34 115/208-230
None
6.4
12.25
1
1
2
1800 145T
120590
47 115/208-230
None
9.5
13.75
2
1800 182T
131571
60 115/208-230
None
12.6
13.47
WASHGUARD
MOTORS
7()4% %0/89 s 3).',% 0(!3% $#
** These motors are totally enclosed fan cooled.
$
If base is removed, do not reinstall bolts without using washers to
COMPENSATE FOR THE THICKNESS OF BASE
,%%3/. 7!3('5!2$
motors are designed for
enhanced performance
in applications requiring
regular washdown as in food
processing and for application
in wet, high humidity
environments.
7!3('5!2$
motors
retard the entrance of water
during cleaning operations
and release any water that
does enter the motor. Extra
PROTECTION FOR THE MOTOR S INTERIOR REDUCES RUST AND CORROSION
build-up. Drains release trapped moisture.
-ECHANICAL 0ROTECTION &EATURES
Corrosion resistant 303 stainless
steel shaft with seals and “V” ring seal deflect water, protect
BEARINGS AND THE MOTOR S INTERIOR $OUBLE SEALED BEARINGS WITH HIGH
temperature, moisture resistant lubricant are used.
Cast conduit box with threaded entrance, drain holes and tough,
HIGH TEMPERATURE NITRILE GASKETS #ONDUIT BOX COVER IS STAINLESS
steel.
Four drains in each ENDSHIELD PURGE WATER REGARDLESS OF THE MOTOR S
MOUNTING -ACHINED FITS ARE SEALED AND NYLON GASKETS ARE USED TO
seal bolt heads. Stainless steel data plate.
Fan cooled designs utilize a chemically inert static free fan. Heavy
gauge type 304 stainless steel fan cover in frames 56 through 145T.
Fan cover is epoxy coated for frames 182T and larger.
%LECTRICAL &EATURES
High efficiency copper windings. Service
Factors are 1.15 or greater, with Class F insulation system. High
torques exceed NEMA performance standards.
Single phase motors use a field proven electronic solid state
encapsulated starting switch.
&OR FURTHER INFORMATION ON ,%%3/. 7!3('5!2$˜ MOTORS
REQUEST "ULLETIN
WASHGUARD
WASHDOWN MOTORS
V
All three phase motors, 1HP and above, are inverter rated.