42
Specifications are subject to change without notice
AC Motors
ÓänÓÎäÉ{Èä6ÊUÊ/ 6É/ ÊUÊ Ê
Ê7 / Ê -
RPM
App.
F.L.
%
“C”
60
NEMA
Catalogue
Wgt.
Amps
F.L.
Dim.
HP
Hz
Frame
Number
(lbs.)
Voltage
230V
Eff.
(Inches)
1/3
3600 56C
191200
L
29
208-230/460
1.0
74.0
9.78
3600 56C
191535
34
208-230/460
0.49
72.0
10.70
1800 56C
191201
L
30
208-230/460
1.3
78.5
9.78
1800 56C
191529
35
208-230/460
0.53
75.0
11.20
1/2
3600 56C
191203
L
32
208-230/460
1.5
77.0
9.78
3600 56C
191501
37
208-230/460
0.68
76.0
10.70
1800 56C
191204
L
33
208-230/460
1.6
81.5
9.78
1800 56C
191530
38
208-230/460
0.81
78.0
11.20
3/4
3600 56C
191206
L
33
208-230/460
2.0
78.5
9.78
3600 56C
191502
40
208-230/460
0.96
79.0
10.70
1800 56C
191207
L
38
208-230/460
2.3
82.5
9.78
1800 56C
191531
43
208-230/460
1.1
80.0
11.20
1
3600 56C
191209
41
208-230/460
2.6
80.0
13.77
3600 143TC
'
42
208-230/460
2.6
80.0
13.62
3600 143TC
191486
W
42
208-230/460
2.6
80.0
13.62
1800 56C
191291
L
49
208-230/460
3.0
81.0
11.00
1800 56C
191211
47
208-230/460
3.0
82.5
13.77
1800 143TC
'
48
208-230/460
3.0
82.5
13.62
1800 143TC
191487
W
48
208-230/460
3.0
85.5
13.62
1
1
⁄
2
3600 56C
191215
48
208-230/460
3.8
82.5
13.77
3600 143TC
'
49
208-230/460
3.8
82.5
13.62
3600 143TC
191488
W
49
208-230/460
3.8
84.0
13.62
1800 56C
191217
48
208-230/460
4.8
84.0
13.77
1800 145TC
'
49
208-230/460
4.8
84.0
13.62
1800 145TC
191489
W
49
208-230/460
4.8
86.5
13.62
2
3600 56C
191221
49
208-230/460
5.0
84.0
13.77
3600 145TC
'
50
208-230/460
5.0
84.0
13.62
3600 145TC
191490
W
50
208-230/460
5.0
85.5
13.62
1800 56C
191223
52
208-230/460
5.8
84.0
13.77
1800 145TC
'
53
208-230/460
5.8
84.0
13.62
1800 145TC
191491
W
53
208-230/460
5.8
86.5
13.62
3
3600 145TC
'
62
208-230/460
7.4
85.5
14.12
3600 145TC
191492
W
62
208-230/460
7.4
86.5
14.12
App.
F.L.
%
“C”
NEMA
Catalogue
Wgt.
Amps
F.L.
Dim.
Frame
Number
(lbs.)
Voltage
575V
Eff.
(Inches)
56C
191227
L
29
575
0.45
74.0
9.78
56C
191503
34
575
0.42
72.0
10.70
56C
191228
L
30
575
0.52
78.5
9.78
56C
191532
35
575
0.51
75.0
11.20
56C
191230
L
32
575
0.65
77.0
9.78
56C
191504
37
575
0.81
76.0
10.70
56C
191231
L
33
575
0.65
81.5
9.78
56C
191533
38
575
0.79
78.0
11.20
56C
191233
L
33
575
0.80
78.5
9.78
56C
191505
40
575
1.1
79.0
10.70
56C
191234
L
38
575
0.95
82.5
9.78
56C
191534
43
575
1.1
80.0
11.20
56C
191236
41
575
1.2
80.0
13.77
143TC
191237
42
575
1.2
80.0
13.62
143TC
191518
W
42
575
1.0
80.0
13.62
56C
191295
L
47
575
1.2
82.5
11.00
56C
191238
47
575
1.2
82.5
13.77
143TC
191239
48
575
1.2
82.5
13.62
143TC
191519
W
48
575
1.2
85.5
13.62
56C
191242
48
575
1.7
82.5
13.77
143TC
191243
49
575
1.7
82.5
13.62
143TC
191520
W
49
575
1.5
84.0
13.62
56C
191244
48
575
1.9
84.0
13.77
145TC
191245
49
575
1.9
84.0
13.62
143TC
191521
W
49
575
1.9
86.5
13.62
56C
191248
49
575
2.2
84.0
13.77
143TC
191249
50
575
2.2
84.0
13.62
145TC
191522
W
50
575
2.0
85.5
13.62
56C
191250
52
575
2.3
84.0
13.77
145TC
191251
53
575
2.3
84.0
13.62
145TC
191523
W
53
575
2.3
86.5
13.62
145TC
191297
62
575
3.0
85.0
14.12
145TC
191524
W
62
575
3.0
86.5
14.12
xÇx6ÊUÊ/ 6É/ ÊUÊ Ê
Ê7 / Ê -
C
ONFORMITE
E
UROPEENE
Standards and Approvals
UL component recognized, file number E57948, guide number
02'9 %NERGY EFFICIENCY RATINGS ARE VERIFIED BY AN
independent testing laboratory. CSA Energy Efficiency
Verification Program, report number EEV 78720-1. Construction
is CSA Certified for safety report number LR33543.
WASHGUARD
™
SST
™
ALL STAINLESS
4(2%% 0(!3% s
6/,43
All three phase motors, 1HP and above, are inverter rated.
L
These motors are totally enclosed, non-ventilated—Others are fan cooled.
W
Premium efficiency WATTSAVERe
®
Motors.