20
        
        
          
            Refrigeration
          
        
        
        
          120 & 208/230 Volt Technical Specifications
        
        
          
            Aspera
          
        
        
          
            Part #
          
        
        
          
            Nominal
          
        
        
          
            Motor HP
          
        
        
          
            BTU Capacity
          
        
        
          
            LBP
          
        
        
          
            Volts
          
        
        
          
            59-NE2125GK
          
        
        
          *
        
        
          1/4+
        
        
          1354
        
        
          120
        
        
          
            59-NE2134GK
          
        
        
          *
        
        
          1/3+
        
        
          2048
        
        
          120
        
        
          
            59-T2155GK
          
        
        
          *
        
        
          1/2
        
        
          2341
        
        
          120
        
        
          
            59-T2168GK
          
        
        
          *
        
        
          3/4
        
        
          3135
        
        
          120
        
        
          
            59-T2178GK1
          
        
        
          *
        
        
          3/4+
        
        
          3659
        
        
          120
        
        
          
            59-T2178GK2
          
        
        
          *
        
        
          3/4+
        
        
          3659
        
        
          208/230
        
        
          
            59-J2192GK
          
        
        
          *º
        
        
          1
        
        
          4548
        
        
          208/230
        
        
          
            59-J2212GK
          
        
        
          *º
        
        
          1 1/4
        
        
          5960
        
        
          208/230
        
        
          º Complete with Service Valve
        
        
          *Above compressors are all high starting torque and come complete with capacitor.
        
        
          
            R404A Refrigeration Compressors
          
        
        
          BTU Rating Conditions
        
        
          
            Back Pressure
          
        
        
          
            Low
          
        
        
          130°F
        
        
          Condensing
        
        
          Temperature
        
        
          -10°F
        
        
          Evaporator
        
        
          Temperature
        
        
          90°F
        
        
          Return Gas
        
        
          Temperature
        
        
          90°F
        
        
          Ambient
        
        
          Temperature
        
        
          90°F
        
        
          Liquid Temperature
        
        
          Entering Expansion Valve
        
        
          
            59-J2168GK
          
        
        
          Illustrated
        
        
          Refrigeration & Air Conditioning Compressors
        
        
          For All Your Cooling Solutions
        
        
          • Reliability
        
        
          • Efficient
        
        
          • Silent Operating
        
        
          • 30 Month Warranty
        
        
          Electrical Assemblies
        
        
          
            Aspera Part #
          
        
        
          
            Relay
          
        
        
          
            Overload
          
        
        
          
            Start
          
        
        
          
            Capacitor
          
        
        
          
            Run
          
        
        
          
            Capacitor
          
        
        
          
            59-E2125GK
          
        
        
          59-9660182
        
        
          59-MRT22AIN 35-145B165
        
        
          -
        
        
          
            59-E2134GK
          
        
        
          59-9660183
        
        
          59-MRT20JZ
        
        
          35-189D165
        
        
          -
        
        
          
            59-T2155GK
          
        
        
          59-9660191
        
        
          59-MST16RN 35-145B165
        
        
          -
        
        
          
            59-T2168GK
          
        
        
          59-3ARR188S
        
        
          59-CST3031
        
        
          35-145B165
        
        
          -
        
        
          
            59-T2178GK1
          
        
        
          59-3ARR10A3
        
        
          Internal
        
        
          35-88F330
        
        
          36-15R3744
        
        
          
            59-T2178GK2
          
        
        
          59-3ARR3B10A3
        
        
          Internal
        
        
          35-88F330
        
        
          36-15R3744
        
        
          
            59-J2192GK
          
        
        
          59-3ARR3AB3
        
        
          Internal
        
        
          35-88F330
        
        
          36-20R3744
        
        
          
            59-J2212GK
          
        
        
          59-ARR3AV3
        
        
          Internal
        
        
          35-88F330
        
        
          36-20R3744
        
        
          Compressors
        
        
          Crankcase Heaters
        
        
          Self
        
        
          Regulating!
        
        
          
            "Compressor Burnout Protection!"
          
        
        
          • When a refrigeration compressor shuts down or enters a long-off cycle, liquid
        
        
          refrigerant migrates into its crankcase oil.  Lubrication decreases and crankcase
        
        
          burnout can occur when operation resumes.
        
        
          • Energy efficient, self-regulating design automatically varies output to maintain
        
        
          adequate oil temperature while permitting wrapping and crossover without burnout.
        
        
          • Handles compressors up to 5 Hp, 120 or 240 volt applications.
        
        
          • Fits all crankcases with circumferences smaller than 49".
        
        
          
            75-CCH1
          
        
        
          Illustrated
        
        
          
            Part # Volts Output @
          
        
        
          -18°C (0°F)
        
        
          
            Output @
          
        
        
          16°C (60°F)
        
        
          
            75-CCH1
          
        
        
          120
        
        
          60W 35W
        
        
          
            75-CCH2
          
        
        
          240